Heat Pump Not Heating? Causes, Safe Checks and Costs

Some cool-feeling air is normal for a heat pump, and so is a short defrost cycle in cold weather. When the house won't warm up at all, the cause is often a thermostat setting, a dirty filter or a blocked outdoor unit. A refrigerant leak, a stuck reversing valve or a failed part needs a technician.

Stop and call a pro now if

  • You smell burning or see smoke from the indoor unit or the outdoor unit. Turn the system off at the thermostat and the breaker, and call a technician.
  • A breaker for the heat pump trips again after you reset it once.
  • The outdoor unit stays encased in ice for hours and never defrosts. Turn it off and call a technician rather than chipping the ice.

Likely causes

  • Normal heat pump air feels cool

    Trane notes heat pump supply air is often around 85 to 93 degrees, which feels cool on your hand compared with a furnace. If the house holds temperature, this is normal.

  • The unit is in a defrost cycle

    In cold, damp weather the outdoor coil frosts over and the heat pump reverses briefly to melt it. Carrier puts a defrost cycle at about 5 to 10 minutes, and you may see steam outside.

  • Thermostat settings

    Trane lists a thermostat left on Cool, or a fan set to On instead of Auto, as a common cause of cool air between cycles.

  • A dirty filter or blocked outdoor unit

    A clogged filter cuts airflow. Leaves, snow or ice packed around the outdoor unit stop it moving heat. Carrier recommends about 24 inches of clearance around it.

  • A tripped breaker or disconnect

    Carrier notes the indoor and outdoor units usually have separate breakers and the outdoor unit has a disconnect switch. If the outdoor one is off, only backup heat runs, if any.

  • A refrigerant leak

    Low refrigerant leaves the system short of heat. Hissing near the lines or a coil that ices up are signs.

  • A stuck reversing valve or failed defrost control

    If the reversing valve sticks, the system can blow cold air constantly. A failed defrost control lets the outdoor coil ice over.

What you can safely check

These checks only use the thermostat, the filter and your eyes on the outdoor unit.

  1. Check the thermostat

    Set it to Heat, the fan to Auto, and the temperature a few degrees above the room. Replace the batteries if the display is dim.

  2. Wait out a defrost

    If the outdoor fan has stopped and you see steam, give it about 10 minutes before deciding anything is wrong.

  3. Replace the filter

    Hold it up to a light. If you can't see through it, replace it. Trane suggests changing filters every 1 to 3 months.

  4. Clear the outdoor unit

    Brush away leaves and snow and keep about 24 inches clear around it. Make sure snow isn't piled against the base or dripping onto it from the roof.

  5. Check both breakers and the disconnect

    Look for tripped breakers for the indoor and outdoor units, and check that the disconnect box near the outdoor unit is on.

  6. Use emergency heat only as a stopgap

    If the outdoor unit isn't running, Carrier suggests switching the thermostat to emergency heat to keep the house warm until a technician comes. It costs more to run.

Avoid these

  • Chipping or prying ice off the outdoor coil, or pouring boiling water on it. The fins and coil tubes bend and puncture easily.
  • Opening the outdoor unit's electrical panel. The capacitor holds a charge even with the power off.
  • Running on emergency heat for weeks instead of getting a repair.

When to call a pro

  • The air stays cold with the right settings, a clean filter and a clear outdoor unit.
  • The outdoor unit is iced over and doesn't clear after a defrost cycle.
  • You hear hissing or see oily residue on the refrigerant lines.
  • The outdoor fan or compressor won't start, or a breaker keeps tripping.

Tell the technician the system's age, the outdoor temperature when it happened, whether the outdoor fan runs, and whether you see ice. That separates a defrost, refrigerant, reversing valve or electrical problem before the visit.

Typical repair costs

National ranges for parts and labor from HomeGuide and HomeAdvisor. Refrigerant type and system access change the total.

Repair Typical cost Source
HVAC service call $75–$200 HomeGuide
Capacitor replacement $100–$250 HomeGuide
Contactor replacement $150–$400 HomeGuide
Defrost control board $200–$650 HomeAdvisor
Refrigerant leak repair $200–$1,500 HomeGuide
Compressor replacement $1,300–$2,500 HomeGuide

A compressor failure on an older heat pump is often the point where replacement makes more sense than repair. Ask for both prices.

Frequently asked questions

Why does my heat pump blow cold air?

Heat pump air is cooler than furnace air, often 85 to 93 degrees, so it can feel cool. Cold air for a few minutes in winter is usually a defrost cycle. Cold air that doesn't stop points to a setting, airflow or refrigerant problem.

How long does a heat pump defrost cycle last?

Carrier puts it at about 5 to 10 minutes. Steam from the outdoor unit and a stopped fan during that time are normal.

Should I switch to emergency heat?

Only if the outdoor unit isn't working and you need heat until a technician arrives. Emergency heat uses your backup heat, usually electric heat strips or a furnace, and electric strips cost more to run.

Can a heat pump heat in very cold weather?

Yes, though it works harder and relies more on backup heat as temperatures drop. If the house won't hold temperature on milder days, something is wrong.