Furnace Leaking Water? Causes, Safe Checks and Costs

High-efficiency furnaces make water as part of normal operation and drain it away through a line or a small pump. Water on the floor usually means that drain path is clogged, cracked or not pumping. Less often it comes from a humidifier, or from a heat exchanger problem, and that one is a safety issue.

Stop and call a pro now if

  • Water is reaching the furnace's electrical parts or wiring. Turn the furnace off at its switch if you can reach it without standing in water, and call a technician.
  • Your carbon monoxide alarm sounds. Get everyone outside and call 911.
  • You smell gas. Leave and call your gas utility or 911 from outside.

Likely causes

  • A clogged condensate drain line or trap

    The most common cause. Furnaces rated 90% AFUE and above condense water out of the exhaust and send it to a drain. Algae, sludge or debris in the line backs the water up until it spills.

  • A failed or unplugged condensate pump

    If there is no floor drain nearby, a small pump lifts the water to a drain. A full reservoir, an unplugged cord, a tripped outlet or a dead pump lets it overflow.

  • A cracked or disconnected drain line

    Lines can sag, pull off their fittings or crack, especially where they run along the floor. The small hoses inside the cabinet that drain the inducer and collector box can also crack or slip off.

  • The air conditioner's drain

    In summer, the AC's indoor coil, which usually sits on top of the furnace, makes its own condensate. A clogged AC drain, or a frozen coil thawing, drips down the furnace cabinet. It is one of the most common reasons for water around a furnace.

  • A frozen condensate line in winter

    A line run through a cold garage, crawlspace or outdoors can freeze, and water then backs up at the furnace.

  • A humidifier leak

    A whole-house humidifier mounted on the ductwork has its own water supply and drain. A stuck valve or loose tubing can drip onto or beside the furnace.

  • A heat exchanger problem

    Less common but serious. Corrosion or a crack in the heat exchanger can show up as water or rust inside the cabinet, and it can let combustion gases into the airflow.

What you can safely check

Put a towel or pan under the drip first, then trace where the water is coming from. Look, but don't take anything apart.

  1. Figure out what kind of furnace you have

    White PVC exhaust and intake pipes usually mean a high-efficiency condensing furnace that is supposed to make water. A metal flue usually means a standard-efficiency furnace. Water on one of those can mean exhaust gases are condensing in the vent, which is a venting problem. Turn it off and have it checked promptly.

  2. Rule out other sources

    Make sure the water isn't coming from a nearby water heater, pipe or humidifier.

  3. Follow the drain line

    Trace the small tube from the furnace to the floor drain or pump. Look for kinks, sags, a fitting that has pulled loose, or a line that runs through a cold space.

  4. Check the condensate pump

    If there is a pump, make sure it is plugged in and the outlet works. A reservoir full of water with the pump silent means the pump or its float switch has failed. Many pumps have a safety switch that shuts the system off when the reservoir is full, so no heat plus a full pump points to the pump.

  5. Check the humidifier

    If water is coming from the humidifier on the ductwork, close its supply valve and leave it off until it is serviced.

  6. Check the filter

    Replace a dirty filter. In cooling season, a clogged filter can freeze the AC coil, which drips as it thaws.

Avoid these

  • Opening the burner compartment or inspecting the heat exchanger.
  • Running the furnace with water dripping on its control board or wiring.
  • Pouring chemicals into the condensate trap or pump unless your manual says to.

When to call a pro

  • The drain line or trap is blocked somewhere you can't see or reach.
  • The condensate pump runs but doesn't empty, or doesn't run at all.
  • You see water or rust inside the furnace cabinet. Turn the furnace off and have the heat exchanger and drains checked.
  • A standard-efficiency furnace with a metal flue is leaking.
  • The leak comes back after the line is cleared.

Ask the technician to check the heat exchanger and venting while they clear the drain, especially on an older furnace.

Typical repair costs

National ranges from HomeGuide. Most leaks are a cleared or replaced drain line or pump, which falls in the leak-repair range.

Repair Typical cost Source
Furnace leak repair (drain line, trap or pump) $100–$400 HomeGuide
Typical furnace repair $125–$480 HomeGuide
Heat exchanger replacement $1,000–$3,000 HomeGuide
Annual furnace tune-up $70–$200 HomeGuide
HVAC labor $75–$150 per hour HomeGuide

HomeGuide notes that clogged condensate lines and pumps are the most common cause of leaks on high-efficiency furnaces. A heat exchanger replacement on an older furnace is often weighed against a new furnace.

Frequently asked questions

Is it normal for a furnace to drain water?

Yes, for a high-efficiency furnace. It produces condensate that should run through a drain line or pump. It should never pool on the floor.

Is a furnace leaking water an emergency?

It can be. Water near electrical parts is a shock and damage risk, and a leak caused by a damaged heat exchanger can carry a carbon monoxide risk. Turn the furnace off and call a pro if either applies.

Why does my furnace leak only in winter?

The furnace runs more and makes more condensate in winter, so a partly clogged line overflows. A line through a cold space can also freeze.

Could the water be from my air conditioner?

In summer, yes. The AC's indoor coil usually sits on top of the furnace and drains its own condensate. A clogged AC drain can drip down the furnace cabinet.

Sources

  1. Furnace Leaking Water: Causes, Signs, and Solutions , Carrier
  2. Furnace Repair Cost (2025) , HomeGuide