1. Not running Cat6A ethernet to every room
Wi-Fi is convenient but unreliable for high-bandwidth, latency-sensitive applications: 4K streaming, video calls, gaming, security cameras, and home automation hubs. Running Cat6A cable to every room during a renovation costs $50–$100 per drop — materials and labor included while walls are open. Retrofitting ethernet after drywall is $300–$500 per drop, involves fishing cables through insulated cavities, and often requires visible surface raceways. Run more drops than you think you need.
Pro tip: Run two drops to every entertainment location (TV wall, desk, gaming area) and one to every bedroom. Run a dedicated drop for each security camera location. Cat6A supports 10-gigabit speeds, which future-proofs you for the next 15–20 years.
2. Forgetting neutral wires at switch locations
Most smart switches require a neutral wire at the switch box to power their Wi-Fi radio and internal electronics. Older homes — and some newer homes with 'switch loop' wiring — only have a hot wire and a traveler at the switch, with the neutral at the fixture. Running a neutral wire to a switch box requires access to the wall cavity. During renovation, adding a neutral to every switch box costs virtually nothing. After drywall, it's a major project or a dead end.
Pro tip: Even if you aren't planning smart switches today, insist that your electrician run 14/3 (with neutral) to every switch box. The marginal cost during construction is $5 per switch — the retrofit cost is $200+.
3. Not pre-wiring for ceiling-mounted devices
Ceiling-mounted access points, speakers, projectors, and cameras need power and data at their mounting location. Running cables to the ceiling center of every major room — living room, master bedroom, hallway — during renovation gives you options for wireless access points, flush-mount speakers, or surveillance cameras later. Without pre-wire, you're stuck with surface-mounted hardware and visible cables, or an expensive post-construction retrofit.
Pro tip: For each ceiling location, run one Cat6A cable and one 14/2 power cable to a junction box. This covers every conceivable ceiling-mounted device — AP, speaker, camera, or projector.
4. Using a single Wi-Fi router instead of planning for access points
A single router in the basement or home office cannot reliably cover a multi-story home through walls, floors, and ceilings. Hardwired access points — one per floor, ceiling-mounted — provide consistent coverage everywhere. But ceiling-mounted APs require ethernet and power at the ceiling location, which can only be run economically during renovation. The AP hardware costs $100–$200 per unit. The pre-wire costs $50–$100 per location during renovation, or $500+ after.
Pro tip: Plan AP locations at the center of each floor's living space, not against an exterior wall. Central placement maximizes coverage radius. Use PoE (Power over Ethernet) access points to avoid running separate power cables.
5. Not installing a structured wiring panel or closet
Every ethernet, coax, and low-voltage cable in your home should terminate at a central location — a structured wiring panel or a dedicated closet. Without a central point, cables dead-end at random locations, making network changes, troubleshooting, and expansion difficult. During renovation, designating a closet or panel location and routing all cables there is straightforward. After construction, rerouting cables is impractical.
Pro tip: The structured wiring location needs a dedicated electrical outlet for the network switch, router, and any PoE injectors. Don't forget power when planning the data closet.
6. Ignoring outdoor pre-wire for cameras, lighting controls, and speakers
Outdoor security cameras, smart landscape lighting transformers, outdoor speakers, and gate controllers all need power and/or data at specific exterior locations. Running cables through exterior walls after construction means drilling through siding, flashing, and weather barriers — creating water intrusion points. During renovation, routing cables to exterior locations through the wall cavity before siding is installed is clean, weatherproof, and inexpensive.
Pro tip: For each exterior camera location, run Cat6A to a weatherproof box at soffit level. Soffit-mounted cameras have better angles, are harder to tamper with, and the cable entry point is protected by the overhang.
Bonus Tip
Document every cable run with photos and a spreadsheet before walls close
Once drywall covers your pre-wiring, the cable routes become invisible. Photograph every wall cavity showing cable routing, label both ends of every cable with a numbered tag, and create a spreadsheet mapping each cable number to its start point, end point, and cable type. This documentation saves hours of troubleshooting and prevents accidentally drilling into cables during future projects.
What to Avoid
- Running Cat5e instead of Cat6A to save $20 per run — Cat5e is already obsolete for 10-gigabit networking and you'll be re-running cable in 5 years.
- Putting the structured wiring panel in the attic where it's impossible to service in summer — choose a climate-controlled, accessible location.
- Using wireless-only security cameras to avoid pre-wiring — batteries die, Wi-Fi drops, and stolen cameras take the footage with them.
- Assuming your electrician knows low-voltage — electrical and low-voltage are different trades; many electricians don't terminate data cable correctly.