1. No permit was pulled and no inspection is scheduled
If your electrician started work without mentioning a permit, they're skipping it. Permits exist so an independent inspector verifies the work meets code. Without a permit, no one checks the electrician's work, you have no recourse if something fails, and the work becomes an undisclosed issue at resale. In most jurisdictions, the contractor — not the homeowner — is responsible for pulling permits. Ask to see the permit before work begins.
Pro tip: Call your local building department and ask if a permit has been pulled for your address. This takes 5 minutes and confirms whether the electrician is being truthful.
2. Wire runs are not secured and hang loosely in the framing
NEC requires cables to be stapled or supported within 12 inches of every box and at intervals no greater than 4.5 feet. Cables draped loosely across joists, hanging from nails, or run diagonally through stud bays without support are code violations. Unsecured cables get snagged by other trades, crushed by insulation, and develop stress at connections. Properly securing cables takes an extra 10 minutes per circuit — the only reason to skip it is laziness.
Pro tip: Check the attic and basement after the electrician leaves. If cables are loose, unsupported, or run across the top of joists where they'll be stepped on, the work is substandard.
3. Junction boxes are left open without covers
Every junction box must have a cover plate — no exceptions. An open junction box exposes live wire connections to physical damage, dust, insulation, and anything else in the wall or ceiling cavity. It also makes the splice invisible and unfindable for the next person who works on the system. Missing junction box covers are the most common code violation found in residential electrical work, and they indicate a pattern of carelessness.
Pro tip: Ask the electrician to mark every junction box location on your floor plan. Buried junction boxes are a nightmare for future troubleshooting.
4. Ground wires are not connected — just folded back into the box
Grounding is the safety path for fault current. An unconnected ground wire means the equipment ground is broken — the outlet or fixture has no fault protection. Some electricians push the bare ground wire into the back of the box and connect only the hot and neutral, skipping the 30-second step of connecting the ground. Test every outlet with a $15 outlet tester. If it shows 'open ground,' the ground wire is not connected.
Pro tip: Buy a three-light outlet tester and plug it into every outlet the electrician touched. It instantly shows open grounds, reversed polarity, and missing neutrals.
5. Backstabbed connections instead of screw terminals
The back of most residential outlets and switches has 'stab-in' holes that accept wires pushed straight in without wrapping around a screw terminal. Backstab connections rely on a small spring clamp that weakens over time, especially on 20-amp circuits. The wire can pull out, arc, and overheat. Professional electricians use screw terminals or the back-wire clamp (which is different from backstab). If you can pull a wire out of a device with moderate force, it's backstabbed.
Pro tip: Backstab connections are code-legal but inferior. If your electrician is using them exclusively, they're prioritizing speed over longevity. Ask them to use screw terminals on all 20-amp circuits at minimum.
6. Cable sheathing is not stripped properly at the box entry
NEC requires at least 1/4 inch of cable sheathing to extend inside the box, and at least 6 inches of free conductor inside the box. An electrician who strips the sheathing outside the box and feeds bare wires through the knockout leaves the conductors unprotected at the entry point. An electrician who cuts conductors too short makes future device replacement nearly impossible. Both indicate someone who's rushing.
Pro tip: Open one outlet box after the electrician finishes and check: is there at least 6 inches of wire inside the box? Can you easily pull the device out for service? If not, raise it before drywall goes up.
7. The electrician pushes back on the inspection or asks you to 'handle it'
An electrician who does good work welcomes the inspection — it validates their installation and closes out their liability. An electrician who discourages you from scheduling an inspection, asks you to sign off on the work before the inspector comes, or suggests you 'call when you're ready' is avoiding scrutiny. The inspection exists to protect you. Never close walls, make final payment, or sign off on a job until the inspection passes.
Pro tip: Ask to see the inspection result card or permit sticker after the inspector leaves. Passing an inspection means the work met code at that point in time — it's your documented proof of compliance.
Bonus Tip
Take photos of all open-wall wiring before drywall goes up
Once drywall covers the wiring, you cannot see junction boxes, cable routing, support staples, or connections without destructive access. Walk the job with your phone before the rough-in inspection and photograph every box, cable run, and panel connection. These photos become invaluable if you ever need to locate a junction box, trace a circuit, or document a deficiency for a warranty claim.
What to Avoid
- Accepting 'that's how I always do it' as a justification for skipping code requirements — the code doesn't have exceptions for habit.
- Making the final payment before the inspection passes — you lose all leverage once the money is paid.
- Assuming a licensed electrician automatically does code-compliant work — the license means they passed a test, not that they do quality work on every job.
- Letting cost pressure convince you to skip the permit — the $75-$200 permit fee is negligible compared to the cost of tearing out non-compliant work.